# 01, First Floor, Veerasandra Industrial Area, Electronic City Phase 2, Shanthipura, Hoskur Post, Bangalore – 560 099.
At UV Energy Solutions, we provide complete solution for led drivers & led luminaries as per international standards.The drivers are in-house designed by our engineers having necessary expertisein electrical, mechanical and optical design for reliable products.The LED lighting products designed measured up to high test quality standards and have the best quality of materials, thus providing the highest brightness, for both low and high powered LED lighting solutions – for indoor, outdoor and other customised applications.
Model No |
: UV-WG-24W |
Input Power |
: 24W |
Input Voltage& Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 140 – 270 VAC |
Output Voltage |
: 34 – 38 VDC |
Output Current |
: 560mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
≤ 10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 50°C |
Dimensions |
: 98(dia) x 28(H) |
Model No |
: UV-WG-30W |
Input Power |
: 30 W |
Input Voltage & Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 140 – 270 VAC |
Output Voltage |
: 34 – 38 VDC |
Output Current |
: 820 mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
: <10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 50°C |
Dimensions |
: 98(dia) x 28(H) |
Model No |
: UV-WG-35W |
Input Power |
: 35 W |
Input Voltage & Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 140 – 270 VAC |
Output Voltage |
: 34 – 38 VDC |
Output Current |
: 920 mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
: <10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 50°C |
Dimensions |
: 98(dia) x 28(H) |
Model No |
: UV-WG-40W |
Input Power |
: 40 W |
Input Voltage & Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 140 – 270 VAC |
Output Voltage |
: 34 – 38 VDC |
Output Current |
: 1050 mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
: <10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 50°C |
Dimensions |
: 98(dia) x 28(H) |
Model No |
: UV-WG-60W |
Input Power |
: 60 W |
Input Voltage & Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 140 – 270 VAC |
Output Voltage |
: 34 – 38 VDC |
Output Current |
: 1480 mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
: <10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 50°C |
Dimensions |
: 98(dia) x 28(H) |
Model No |
: UV-WG-70W |
Input Power |
: 70 W |
Input Voltage & Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 140 – 270 VAC |
Output Voltage |
: 34 – 38 VDC |
Output Current |
: 1750 mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
: <10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 45°C |
Dimensions |
: 98(dia) x 28(H) |
Model No |
: UV-HB-100W |
Input Power |
: 100 W |
Input Voltage & Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 160 – 270 VAC |
Output Voltage |
: 40 – 48 VDC |
Output Current |
: 2100 mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
: <10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 45°C |
Dimensions |
: 148 (L) x 80 (W) x 36 (H) |
Model No |
: UV-HB-200W |
Input Power |
: 200 W |
Input Voltage & Frequency |
: 220 – 240 VAC, 50 Hz |
Input Functional Range |
: 160 – 270 VAC |
Output Voltage |
: 40 – 48 VDC |
Output Current |
: 4200 mA ±10% |
Efficiency |
: ≥85% |
Power Factor |
: >0.9 |
Athd |
: <10% |
Protection |
: overvoltage, over temperature, short circuit, open circuit |
Ambient Temperature |
: -10°C to 45°C |
Dimensions |
: 180 (dia) x 36 (H) |
--are also available.
Input Wattage (W) |
Input Voltage (VAC), 50Hz |
Input Functional Range (VAC) |
Output Voltage (VDC) |
Output Current (mA) |
Efficiency (%) |
Power Factor |
ATHD (%) |
Protection |
Ambient Temperature (°C) |
Dimensions (mm) |
24W |
220-240 |
140-270 |
34-38 |
560±10% |
≥85% |
>0.9 |
<10% |
overvoltage, over temperature, short circuit, open circuit |
-10°C to 50°C |
98(dia) x 28(H) |
30W |
220-240 |
140-270 |
34-38 |
820±10% |
98(dia) x 28(H) |
|||||
35W |
220-240 |
140-270 |
34-38 |
920±10% |
98(dia) x 28(H) |
|||||
40W |
220-240 |
140-270 |
34-38 |
1050±10% |
98(dia) x 28(H) |
|||||
60W |
220-240 |
140-270 |
34-38 |
1480±10% |
98(dia) x 28(H) |
|||||
70W |
220-240 |
140-270 |
34-38 |
1750±10% |
-10°C to 45°C |
98(dia) x 28(H) |
||||
100W |
220-240 |
160-270 |
40-48 |
2100±10% |
-10°C to 45°C |
148(L)x80(W)x36(H) |
||||
200W |
220-240 |
160-270 |
40-48 |
4200±10% |
-10°C to 45°C |
180(dia) x 36(H) |
© UV energy Solutions Pvt. Ltd 2018 | All rights reserved Privacy Policy